Date: Fri, 29 Mar 2024 10:36:46 +0000 (UTC) Message-ID: <1495093561.47.1711708606976@de048a07b5c1> Subject: Exported From Confluence MIME-Version: 1.0 Content-Type: multipart/related; boundary="----=_Part_46_170457465.1711708606975" ------=_Part_46_170457465.1711708606975 Content-Type: text/html; charset=UTF-8 Content-Transfer-Encoding: quoted-printable Content-Location: file:///C:/exported.html
If you have a valid Calnex Support Service (CSS) contract, the l= atest Paragon-X software can be downloaded from the Calnex Software Download site. Release not= es are also available from the same location.
A Software Download login is required to access the software download ar= ea. If you do not yet have a login, please contact support@calnexsol= .com.
The X.10.42.15 release includes CAT and PFV v29.10.
802.1AS Reverse Sync Time Error Measurement
[PX-5175] SMPTE profiles do not capture management messages
[PX-5166] Delta-Mode Field intermittently set incorrectly in capture fil= es
[PX-5165] Flow Wizard does not display message types with newer versions= of Wireshark
[PX-5162] Wander Transfer Table dwell time is not configurable for some = frequencies
[PX-5147] ToD serial alarm string not decoded correctly NTPv4
[PX-5142] ICMPv6 ND packet not standard
[PX-5139] Sequence ID error incorrectly reported for PeerDelay_Resp_Foll= owUp message type
[PX-5095] Get InstrumentStatus Capture "PTP" IsRunning always returns fa= lse
[PX-5073] Edge case, no Peer Delay Response or Peer Delay Response Fups = sent by Master 1
[PX-3240] MSE Boundary Clock corruption: Timestamp Jump
The X.10.41.17 release includes CAT and PFV v25.20.
802.1AS-2020 profile and PFV rules
AES67 profile and PFV rules
AES67+SMPTE profile and PFV rules
[PX-4754] Modifications have been made in this release to the calculatio= n of Turnaround Time in Peer-to-Peer PTP emulation mode, removing the poten= tial for incorrect results in approximately 1/100-200 test runs. It should = be noted that the issue caused results which were clearly in error.
[PX-5095] InstrumentStatus Capture PTP isRunning incorrectly repor= ts status
[PX-5114] Measure Link Delay selection not cleared on a Recall Factory S= ettings
[PX-5115] Added check to report incompatible settings file when reloadin= g a configuration from a previous software release
[PX-5117] Change Profile display to Custom in 1588-2008 Profile if= alternateMasterFlag is set TRUE
[PX-5118] Configure capture settings for 1588 1 step/2step are not reset= to 1step on a Recall Factory Settings
[PX-5119] Reset to defaults added before loading a saved configuration f= ile
[PX-5120] Change Profile display in Master/Slave Emulation to Cust= om if PortNumber or ClockIdentity is all 0s or all 1s (ffff..)
[CAT-6377] PTP V3 file export as CSV then reimport loses V3 content
<= /li>[CAT-6393] CAT/PFV Components have a dependency on VC runtime 2015, if m= issing causes CAT to fail to run from Paragon-X
The X.10.41.07 release includes CAT and PFV v25.00.
Added support for peer-to-peer devices that use software timestamping. F= or peer-to-peer devices that timestamp prior to the device edge, the Parago= n-X can now use a calculated mean path delay and so no longer requires the = user to specify the delay to their timestamper.
CAT: Added support for cascaded media convertors. Allows testing to ITU-= T G.8273.2 and G.8262 for transmission technologies other than ethernet wit= h two devices acting as back-to-back media convertors.
[PX-4969] In MSE mode, port 1 should not be selectable for SyncE wander = measurement
[PX-5019] 1588-2008 profile =E2=80=93 specific Annex J setting options= p>
[PX-5025] Configure Capture setting for 1/2-step appears to affect CAT P= DV measurements
[PX-5035] Displayed PTP offset in Settings Display window is wrong in MS= E mode if G.8275.1 profile is used
[PX-5045] ESMC Port1 Rx State is not captured when running BC mode test = and capturing at the Slave
[PX-5049] Need to change Paragon-X Thru Mode Filtering to enable identif= ication of Delay Responses for individual Slaves when in Multicast mode
=[PX-5060] SyncE Wander Transfer: When Enhanced Defaults are selected, th= e Lower Limit should be enabled
[PX-5074] 802.1AS default Scaled Offset Log Variance has changed from 0x= 4100 to 0x436a
The X.10.40.18 release includes CAT and PFV v24.00.
CAT: Adds support for the ITU-T G.8271.2 pk-pk time error limit
CAT: Double-click .cdf now opens the CAT and loads the file
Announce messages are now included in the default capture filter setting= s when using the Start measurement button in MSE
Ethernet and 1pps cable delay maximum value changed from 1us to 5us
<= /li>[PX-5020] Recording a workflow to set flow filters causes 'settings conf= lict' error if MSE is started before filters are set.
[PX-5011] Script Recorder generating wrong Python format for importimpai= rmentdata
[PX-5010] Trying to load an impairment profile that does not exist gives= error "Only files of same capture type can be imported for Replay"
[PX-4999] SyncE Wander Transfer Table incorrectly reporting fail on Gain= for Frequencies above 10Hz
[PX-4990] Configuring TC Test to Unicast results in missing Delay Respon= se messages
[PX-4245] Script Generator issue: when importing flow filters cfd file u= sing P-X GUI, script generator does not generating corresponding commands Note: The commands are now generated but manual editing is required. There = are missing double quote characters round the filename, so the generated sc= ript will fail unless these are added
[PX-4965] Packet loss when SyncE wander being applied at same time as PT=
P generation and measurement.
In release X.10.40.11, an issue was detected which could lead to PTP packet=
s being dropped when SyncE wander was also being generated by the Paragon-X=
,
This release resolves this issue, and the full expected range of PTP packet=
generation and application of SyncE wander stress signals can be applied s=
imultaneously.
[CAT-6109] CAT: No Help available for Metric Time Of Day
[CAT-6096] CAT: Minor error in mask for "G.8262 standard 11.2.1 EEC-Opti= on 1 holdover"
[CAT-6015] CAT: CAT taking many minutes to open very large .clxz file
[CAT-5982] CAT: No Help available for G.8273.2 Noise Transfer (Clause 7.= 3) and Jitter Metrics
[CAT-5972] CAT: DTE Pk-Pk metric on graph no longer turns white when pas= s
[CAT-5894] CAT app goes all-white after extended live capture
[CAT-5864] CAT: Closing CAT while it's loading a live capture file crash= es P-X GUI
[CAT-5772] CAT: Report Generation does not highlight PktoPk failures in = Dynamic Time Error HF metric
[CAT-5404] CAT: Double-click .cdf should open CAT and load file
[PFV-533] PFV: Negative correctionField values handled incorrectly
= li>[PFV-525] PFV: Rules file for G.8265.1 fails for ethernet type when Vlan= s are being used
[PFV-523] PFV: EtherType is incorrect with VLAN enabled
[PFV-517] PFV: Not displaying PTP packets containing >1 VLANS
[PFV-507] PFV: No error returned when trying to select a non-existent ru= les file
[PFV-497] PFV: DSCP value '0' reports fail - it should not