Note: This version of firmware can only be installed on Sentinel instrument with a serial number greater than 00300000. |
Features
Added Metrics and Masks
A range of metric and masks have been added to Sentinel as summarised in the table below:
Associated Standard | Topic | Added Metric | Added Mask |
---|---|---|---|
G.8261 | Frequency Synchronisation | G.8261 Amd.2 Short Chain Network Limits (Fig 19) | |
G.8271.1 | Full Timing Support | 2Way dTE MTIE LF | G.8271.1 dTE MTIE |
G.8271.2 | Partial Timing Support (PTS) and Assisted Partial Timing Support (APTS) | pktSelected2wayTE | G.8271.2 APTS Pk-Pk Network Limit |
Defect Fixes
[SEN-2514] During a 5G OTA measurement, if the signal loses lock and then regains lock the graph doesn’t update
[SEN-2476] During an OTA measurement, the widget was indicating the opposite sign to the graph
R13
Info |
---|
Note: This version of firmware can only be installed on Sentinel instrument with a serial number greater than 00300000. |
Features
HTTP(S) Interface
An HTTP(S) interface has now been added to Sentinel allowing a basic remote control functionality. For full details please refer to the Sentinel User Manual.Continuous Measurements
An option has now been added to the measurement settings page to allow the user to select continuous measurements. This means that Sentinel will continue to make a measurement on a rolling 24 hr basis.IPv6 on the Management Port
There is now the ability to use IPv6 addresses on the management port for Sentinel.Disable SyncE
SyncE can now be disabled independently of PTP/NTP measurements. This feature is available via the mode page.Disable Metrics
If you don’t want to run any metrics or masks you can disable this on the measurement settings page.
...
R11
Features
10GbE functionality
Info |
---|
Notes:
|
Defect Fixes
[SEN-1085] Ethernet Gateway Ping button is enabled when DHCP is enabled
[SEN-1151] Sentinel doesn't reach 128 packets per second for Delay Request rate
[SEN-1726] Configuring Sentinel from Electrical to optical ethernet results in no RevPDV being recorded
[SEN-1781] Apply button will only change IP address / Mask / Gateway setting on the first press
[SEN-1796] Protocol check does not detect Delay Response if multiple PTP multicast flows are present
[SEN-1803] Moving from GNSS settings page with invalid value on antenna delay causes crash
...