Upgrading from version 2.1 and later
The latest software release for Paragon-neo is Release 11, see this FAQ article for details Paragon-neo: Software Releases.
Paragon-neo software releases are distributed from the Calnex Software Download site. Users will receive email notifications from the software download system whenever new software is released.
Upgrading to the latest Paragon-neo
releases,release may require installation of specific intermediate releases
may be required, see table below
.To upgrade from a From Release to a To Release the intermediate releases shown in the intersecting celldetailing the upgrade path. Intermediate releases must be installed in the order shown. E.
gG. to upgrade from
R4R8 to
R8.1R11, first upgrade to
R5R9, then
R7, then R8.1R11. If "Direct" is shown then no intermediate release is required between the versions.
Downgrading is possible however specific steps may be required, therefore this should only be performed with the approval of Calnex Solutions.
To Release
From Release
Intermediate releases can be downloaded from the software download system along with the latest release.
Please contact your Calnex representative if your Paragon-neo is currently running software release 1.0 or 2.0.
Instructions to perform the upgrade are below the table.
From Release | Upgrade steps to R11 |
R10 → | Direct |
R9 → | Direct |
R8.1 → | → R9 → R11 |
R8 → | → R9 → R11 |
R7 → | → R9 → R11 |
R6 → | →R7 → R9 → R11 |
R5 → | →R7 → R9 → R11 |
R4 → | → R5 → R7 → R9 → R11 |
R2.1 → | → R4 → R5 →R7 → R9 → R11 |
What Software Version is my Paragon-neo Running ?
The running software version is shown in the GUI Help → About page. The example screenshot shows software version 9.00.37 from release R9.
Image AddedSoftware Installation Steps
Paragon-neo software is delivered as a tar file (*.tar). Download this file and save it to a location on your PC.
Before upgrading the instrument, you must first stop all generation and capture.
Follow the steps below to upgrade:
- Click System in the menus on the top right of the UI
- Click Setup in the left hand menu bar
- The UI should look something like:
Image Removed
- Click Choose installer file to select the tar file that you saved earlier
The instrument will now begin the upgrade process. Note that this will take a while (maybe as much as an hour). Do not power off while the upgrade is in process.
Upgrading from versions 1.0 or 2.0
The Paragon-neo software may either be delivered as a tar file (*.tar) or as an ISO (*.iso) file (disk image). Upgrading using tar file is preferred but if you would rather use the ISO file, see the instructions below for versions prior to 1.0.
Download the tar file and save it to a location onA text file containing the MD5 checksum of the tar file (*tar.md5) is also available from the same location at the tar file. Follow the instructions in the text file to use the checksum to validate that the tar file has correctly downloaded to your PC.
Before upgrading the instrument, you must first stop all generation and capture
and then re-boot the instrument.
Once the instrument has re-booted, follow theFollow the steps below to upgrade:
Click System in the menus on the top right of the
GUI
Click Setup in the left hand menu bar
The
GUI should look something like:
Click Choose installer file to select the tar file that you saved earlier
The instrument will now begin the upgrade process. Note that this will take a while (maybe as much as an hour). Do not power off while the upgrade is in process.
Upgrading from versions prior to 1.0
Panel | ||
---|---|---|
| ||
Write the ISO image onto a USB stickThe Paragon-neo software is delivered as an ISO (disk image). To upgrade the instrument, this ISO file must be written to a USB stick as an image. To do this, you will need to install an application capable of writing ISO images to USB. One such application is Win32DiskImager. This can be downloaded from http://sourceforge.net/projects/win32diskimager/
Once you have your disk image application installed, run it. You should then load the Paragon-neo ISO file. Using Win32DiskImager:
The ISO should then be written to your USB stick:
Perform the UpgradeYour instrument should be powered on BEFORE you insert the USB stick. In addition, it is not possible to upgrade unless the box is idle - make sure to stop all generation and capture.
Image Removed
The instrument will now begin the upgrade process. Note that this will take a while (maybe as much as an hour). Do not power off while the upgrade is in process. |
Info |
---|
If you do not re-boot prior to attempting the upgrade, the upgrade may fail. In this case, the upgrade process will complete quickly and the version number will remain unchanged. In this situation, you should re-boot and then re-try the upgrade.
Downgrading is possible, however specific procedures may be required depending on the version therefore this should only be performed with the assistance of Calnex, please contact your local Calnex representative for further information. |