Note |
---|
For PAM4 interfaces or SyncE Jitter testing, specific modules MUST be used. These modules have been tested by Calnex to ensure they fulfil the requirements for functionality and performance needed to enable correct operation and guarantee the integrity of the timing measurements. Use of other modules may result in a failed test or incorrect result. More information regarding PAM4 transceivers can be found: https://calnexsolutions.atlassian.net/l/cp/dchS6Mxk For SyncE Wander and PTP on non-PAM4 interfaces, most modules should work correctly; known exceptions are detailed below. If you have a module that is not recognised, please let us know. |
...
400G PAM4 | |||||
Interface | Reach | Manufacturer | Part Number(s) | Software Release When First Supported | Comment |
---|---|---|---|---|---|
QSFP-DD | LR8 10km | Coherent (Finisar) | FTCD1323E1PCL | R7 | Use at 400G rate only. |
QSFP-DD | FR8 2km | Coherent (Finisar) | FTCD1333E1PCL | R7 | Use at 400G rate only. |
QSFP-DD | SR8 100m | Coherent (Finisar) | FTCD8613E1PCM | R7 | Use at 400G rate only. |
QSFP-DD | FR4 2km | Coherent (Finisar) | FTCD4313E1PCL | R7 for FTCD4313E1PCL | Use at 400G rate only. FTCD4313E1PCL works for all scenarios. FTCD4313E2PCL works for all standard conformance tests, however some manually configured SyncE single sine frequency/amplitude combinations can cause link-loss. |
QSFP-DD | LR4 10km | Coherent (Finisar) | FTCD4323E2PCL | R11 | Use at 400G rate only. |
200G PAM4 | |||||
Interface | Reach | Manufacturer | Part Number(s) | Software Release When First Supported | Comment |
QSFP56 | SR4 | Coherent (Finisar) | FTCC8612E1PCM | R9 for FTCC8612E1PCM | FTCC8612E2PCM will be supported in a future release. |
QSFP56 | FR4 | Coherent (Finisar) | FTCC1112E2PCL | R9 | |
100G PAM4 | |||||
Interface | Reach | Manufacturer | Part Number(s) | Software Release When First Supported | Comment |
QSFP28 | DR | Innolight | TR-ZC13H-N00 | R9 | 100G PAM4 optical interface, instrument side is QSFP28 NRZ. Module supports measurement accuracy of ±15ns. See Note 2 below. |
QSFP28 | FR1 | Innolight | TR-ZC13T-N00 | R9 | 100G PAM4 optical interface, instrument side is QSFP28 NRZ. Module supports measurement accuracy of ±15ns. See Note 2 below. |
QSFP28 | LR | Innolight | TR-ZC13L-N00 | R9 | 100G PAM4 optical interface, instrument side is QSFP28 NRZ. Module supports measurement accuracy of ±15ns. See Note 2 below. |
SFP-DD | DR | Flexoptix | P.13S1HG.05.CAL | R11 | Calnex specific transceiver. Please contact Flexoptix for quotation: order@flexoptix.net. See Note 1 below. |
SFP-DD | FR | Flexoptix | P.13S1HG.2.CAL | R11 | Calnex specific transceiver. Please contact Flexoptix for quotation: order@flexoptix.net. See Note 1 below. |
SFP-DD | LR | Flexoptix | P.13S1HG.10.CAL | R11 | Calnex specific transceiver. Please contact Flexoptix for quotation: order@flexoptix.net. See Note 1 below. |
Note1: | Flexoptix transceiver part numbers are Calnex specific, denoted by the letters “CAL” in the part number. Flexoptix may add an extra “-MSA01” suffix to the part number for quotation and ordering purposes (eg P.13S1HG.10.CAL-MSA01). | ||||
Note 2: | Innolight use the same part numbers for TR-ZC13H-N00, TR-ZC13T-N00 and TR-ZC13L-N00 transceivers manufactured in China and Thailand. Calnex have only qualified transceivers manufactured in China. When ordering Innolight transceivers for use with Paragon-neo, please specify that Chinese transceivers are required. | ||||
50G PAM4 | |||||
Interface | Reach | Manufacturer | Part Number(s) | Software Release When First Supported | Comment |
SFP56 | LR | Gigalight | GSS-SPO500-LRCZ | R9 | |
SFP56 | ER | Gigalight | GSS-SPO500-ER | R10 | |
SFP56 | SR | Gigalight | GSS-MPO560-ERSRC | R11 | |
SFP56 | SR | Coherent (Finisar) | FTLF8556E1BCL | R7 |
...
SyncE Jitter
The modules listed below are those that MUST be used for SyncE jitter testing. These modules have been tested by Calnex to ensure that clock recovery can be bypassed and that they have sufficient bandwidth to allow the jitter performance of the device to be tested accurately. These modules are also known to operate correctly for PTP and SyncE Wander.
...
Hirose, LTD1302-BH: Module does not support multi-byte read. Supported by Paragon-neo version 01.00 and later
FS, SFP28-25GSR-85: Some of these modules are configured in a way that Paragon-neo does not recognise; others appear to be OK
Coherent (Finisar), FTLX1472M3BCL: These modules support a range of rates from 8.5Gb/s to 11.3Gb/s for Fibre Channel, SDH/SONET and 10GbE. When the CDR is disabled (which Paragon will do under certain circumstances), the module will set the CDR for 8.5Gb/s Fibre Channel and so no link will be able to be established.