If you have a valid Calnex Support Service (CSS) contract, the latest Tempo release can be downloaded from Software Downloads on the Calnex website. Release notes are also available from the same location.

A CSS login is required to access the software download area. If you do not yet have a login, please register on the site.

Version 2.4.6

Enhancements / Defect Fixes

Version 2.4.1

Enhancements

Improved protocol analysis function with built in packet dissectors for many common protocols including PTP, NTP, DNS, DHCP, ARP, GOOSE and SV. Packet-by-packet delay estimates for time critical protocols.

NTP client and server emulation and NTP test mode including delay and time error measurements.

New family of filters for NTP. Includes different filtering rules to select and classify NTP messages.

More accurate and simple terminology for PTP latency statistics. Now delay standard deviations and ranges are classified as PDV (jitter) rather that PTD (delay) statistics.

Units in Ethernet and IP bandwidth statistics are now user configurable: b/s, kb/s and Mb/s.

Support transmission speeds up to 10 Mb/s in synchronous data communications interfaces: X.21 / V.11, V.35, V.36 (RS-449), EIA-530, EIA-530A.

More accurate terminology for data communications frequency results. Now the unit displays the clock circuit where the frequency was measured.

Generation of custom phase between data and clock circuits (0º, 90º, 180º, 270º) in synchronous data communication interfaces. Measurement of data-to-clock phase in synchronous data communication circuits.

Adds support for the new PHM-24 module supporting an additional E1 or T1 interface in the unit.

More attractive and advanced format for PDF reports. Support for MTIE and TDEV charts and tables in reports.

Graphical export of charts generated from the Event logger function in PDF format.

New Power Management version with more advanced shut down and reboot features.