What Frequencies should be used for testing SyncE Wander Tolerance?

What Frequencies should be used for testing SyncE Wander Tolerance?

SyncE Wander Tolerance using Tones: Option 1 and Enhanced (Tolerance Level 2)

Note that for Enhanced SyncE clocks specified in G.8262.1, there are two tolerance levels; level 2 is the same as the tolerance for standard SyncE clocks as specified in G.8262.

Parameters used:

  • Measured at each corner point in G.8262/Figure 7

  • At least one point per decade

Frequency (Hz)

MTIE Observation Interval (s)

Amplitude
(ns)

Test Time
(Cycles)

Test Time
(s)

Frequency (Hz)

MTIE Observation Interval (s)

Amplitude
(ns)

Test Time
(Cycles)

Test Time
(s)

10

0.032

250

1500

150

1

0.32

250

150

150

0.13

2.5

250

20

154

0.016

20

2000

4

250

0.0032

100

2000

4

1250

0.0008

400

2000

3

3750

0.00032

1000

5000

3

9375

SyncE Wander Tolerance using Tones: Enhanced (Tolerance Level 1)

Parameters used:

  • Measured at each corner point in G.8261/Figure 17

  • At least one point per decade

 

Frequency (Hz)

MTIE Observation Interval (s)

Amplitude

(ns)

Test Time

(Cycles)

Test Time

(s)

Frequency (Hz)

MTIE Observation Interval (s)

Amplitude

(ns)

Test Time

(Cycles)

Test Time

(s)

3.2

0.1

50

1500

469

0.32

1

50

150

469

0.053

6

300

15

283

0.032

10

300

4

125

0.0032

100

300

4

1250

0.00032

1000

300

3

9375

 

Wander Tolerance based on a chain of enhanced clocks:

Figure 17/G.8261 - Network limit for wander (MTIE) at enhanced synchronous equipment clock interfaces

SyncE Wander Tolerance using Tones: Option 2

More information regarding how the tones were selected can be found: G.8262: Wander Tolerance and Transfer for Option II Clocks

Parameters used:

  • Tone amplitudes equal to MTIE mask value at the relevant observation interval of G.824/Figure 3

  • At least one point per decade

Frequency
(Hz)

MTIE Observation Interval (s)

Amplitude
(ns)

Test Time
(Cycles)

Test Time
(s)

Frequency
(Hz)

MTIE Observation Interval (s)

Amplitude
(ns)

Test Time
(Cycles)

Test Time
(s)

3.2

0.1

300

480

150

0.32

1

303

150

469

0.032

10

325

8

250

0.0032

100

550

4

1250

0.0011

280

1000

3

2727

0.00032

1000

1007

3

9375