Paragon-neo: How to use a single port for SyncE Noise Transfer test
Paragon-neo: How to use a single port for SyncE Noise Transfer test
Paragon-neo generates wander by default on Port 2 and measures on Port 1 when using the SyncE Wander pre-set:
However, it is possible to generate and measure SyncE wander transfer both on the same port, this can only be done on Port 2 due to the generation being on the same port.
To do this, change the Capture port to Port 2 in the SyncE Wander Generation app window:
The Capture Port drop down menu is available when selecting one of the Transfer tests:
, multiple selections available,