Paragon-neo: How long does a G8273.2 conformance test take?

There are a number of tests listed in the G.8273.2 menu. How long will it take to run them all?

Answer:

 The time required to run a suite of conformance tests depends on the capabilities of the device being tested and whether tests are run in parallel or not:

For those clauses that apply to multiple outputs such as 7.3.1 and 7.3.2, by default only the named output will be measured, for example PTP to PTP Noise Transfer (Clause 7.3.1) only selects the PTP output

but time can be saved by also enabling the measurement of the 1PPS signal by ticking its box as the input conditions are the same for both measurements

Given that possibility, the approximate duration of a conformance test can be calculated using the following values:

Clause

Duration

Comment

Clause

Duration

Comment

7.1

3h 20m

dTE TDEV limits are defined to τ=1,000s, which means a measurement duration of 12τ

7.2

6h 30m

as per GUI

7.3.1

1h 10m

as per GUI

7.3.2

1h 20m

as per GUI

7.4.1

0h 03m

as per GUI

7.4.2

0h 50m

MTIE is specified to τ=1,000s, which means a measurement duration of 3τ

Thus, assuming measurements for a given clause are run in parallel by measuring both 1PPS and PTP outputs simultaneously, excluding settling and setup time, a measurement time of around 13.5 hours can be expected.