Paragon-X: Can I create a 1588 PDV replay pattern from a list of values
A 1588 PDV replay pattern can be generated from a list of TIE values and that list can then be applied under 1588 Operating Mode (either Master /Slave Emulation configuration or in-line mode ).
The steps involved are:
Create a CSV file containing a single column of values
2. Run a Paragon-X Application and from the Tools Menu select File Converter
3. In the File converter select Convert TIE list for 1588 Replay
4. Select your CSV file
5. And Convert it
Application
To apply these PDV delays
Start the Paragon-X session connecting to the DUT to be tested
Non MSE Mode
Set up the impairment filters using the following steps
Select Flow - Capture Packets
run Flow Wizard
Identify message type to impair
close window
Select Add Impairments/Delay
Ensure it is set to Enabled and Variable Delay Insertion is enabled
You need to select which Port to apply the PDV, for forward select Port 1, for reverse select Port 2
When the Port is selected choose User Defined, click on Import and select the PDV file you saved above
To start the PDV replay press the Start Impairments button at the foot of the page
MSE Mode
press the Add Impairments/Delays button
select Flow Filter to set the message Filter
Selecting Sync will mean that delays will be applied to Master 1 Tx and Delay Request will be applied to Master 1 Rx
Enable Master 1 Tx Delay or Master 1 Rx Delay as required
Select User Defined and press Import to load the saved PDV file
Press the Impairments button at the foot of the display to start the PDV replay