Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Panel

The meaning of the LEDs in these panels varies according to whether the test is running in multicast or unicast mode:

Multicast:

Grey

P-X master was receiving Del_Req messages from the Slave but the P-X master is now inactive

Green

P-X master is receiving Del_Req messages from the Slave

Red

P-X master was receiving Del_Req messages from the Slave but is no longer receiving them

Unicast Auto:

Grey

P-X master had granted the Slave unicast messaging but the P-X master is now inactive

Green

P-X master has granted the Slave unicast messaging

Red

P-X master had granted the Slave unicast messaging but this has expired or the slave cancelled it

Unicast Forced:

Grey

Slave not enabled in configuration, or P-X master is inactive

Green

P-X master is sending Announce/Sync messages to the slave

Red

(Not used)