- Maximum bandwidth: 3Hz
- Minimum bandwidth: 1Hz
- Maximum gain peaking: 0.2dB
- Minimum gain In pass-band: -3dB
- Noise generation allowance: ±5ns
- Two points per decade, extending more than 2 decades below the -3dB point
- Sampling rate: 1kHz
Frequency | Amplitude | Test Time | Test Time | Max. Gain | Min. Gain | Max. Output Amplitude (ns) | Min. Output Amplitude (ns) |
---|
32 | 250 | 2235 | 150 | -5.1 | none | 29 | none |
---|---|---|---|---|---|---|---|
10 | 250 | 1485 | 150 | -3.0 | none | 77 | none |
3.2 | 250 | 480 | 150 | 0.2 | none | 176 | none |
1 | 250 | 150 | 150 | 0.2 | -3.00 | 261 | 171 |
0.32 | 250 | 48 | 150 | 0.2 | -3.00 | 261 | 171 |
0.1 | 320 | 15 | 150 | 0.2 | -3.00 | 333 | 221 |
0.032 | 1000 | 8 | 250 | 0.2 | -3.00 | 1029 | 702 |
0.01 | 2000 | 4 | 400 | 0.2 | -3.00 | 2052 | 1410 |
0.0032 | 2000 | 4 | 1250 | 0.2 | -3.00 | 2052 | 1410 |
SyncE Wander Tolerance using Tones: Option 2
Parameters used:
- Measured at each corner point in G.8262/Figure 7
- At least one point per decade
Frequency (Hz) | MTIE Observation Interval (s) | Amplitude (ns) | Test Time (Cycles) | Test Time (s) |
3.2 | 0.1 | 300 | 480 | 150 |
0.32 | 1 | 303 | 150 | 150 |
0.032 | 10 | 325 | 8 | 250 |
0.0032 | 100 | 550 | 4 | 1250 |
0.0011 | 280 | 1000 | 3 | 2727 |
0.00032 | 1000 | 1007 | 3 | 9375 |