The antenna supplied with Sentinel has a 20m cable, which equates to a delay of 100ns. 

Setting the Sentinel antenna delay while GNSS is connected could cause a step change in the 1PPS phase input to the internal Rubidium oscillator and will require the Sentinel to be re-disciplined for a period of 6 hours. To avoid this the following procedure should be followed.

Panel
  1. In the Settings→MeasurementTimebase page set Internal Reference Disciplining Mode to Never
  2. Press Apply
  3. Connect the GNSS antenna to Sentinel



    NOTE:
    The Rubidium icon will change to a green unlocked padlock.

  4. Select the GNSS tab and enter the Antenna Delay
  5. Press Apply



  6. Wait 10 minutes
  7. Go back to the Settings→MeasurementTimebase page set Internal Reference Disciplining Mode to Always or Not during measurement
  8. Press OK

    Image Modified

    NOTE:
    The Rubidium icon will change to yellow

  9. The Rubidium icon should change to a green locked padlock after 5 minutes.

    Image Modified

  10. Measurements can now be started using the new antenna delay setting.