Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

SyncE Wander Transfer using Tones: Option 1

Parameters used:

  • Maximum bandwidth: 10Hz
  • Minimum bandwidth: 1Hz
  • Maximum gain peaking: 0.2dB
  • Minimum gain In pass-band: -3dB
  • Noise generation allowance: ±20ns
  • Two points per decade, extending more than 2 decades below the -3dB point
  • Sampling rate: 30Hz

Frequency
(Hz)

Amplitude
(ns)

Test Time
(Cycles)

Test Time
(s)

Max. Gain
(dB)

Min. Gain
(dB)

Max. Output Amplitude (ns)

Min. Output Amplitude (ns)

14.9

250

2235

150

-5.1

none

160

none

10.1

250

1485

150

-3.1

none

198

none

3.2

250

480

150

0.2

none

276

none

1

250

150

150

0.2

-3.00

276

156

0.32

250

48

150

0.2

-3.00

276

156

0.1

320

15

150

0.2

-3.00

348

206

0.032

1000

8

250

0.2

-3.00

1044

687

0.01

2000

4

400

0.2

-3.00

2067

1395

0.0032

2000

4

1250

0.2

-3.00

2067

1395

SyncE Wander Transfer using Tones: Enhanced

Parameters used:

  • Maximum bandwidth: 3Hz
  • Minimum bandwidth: 1Hz
  • Maximum gain peaking: 0.2dB
  • Minimum gain In pass-band: -3dB
  • Noise generation allowance: ±5ns
  • Two points per decade, extending more than 2 decades below the -3dB point
  • Sampling rate: 1kHz
Frequency
(Hz)
Amplitude
(ns)
Test Time
(
Cycles
cycles)Test Time
(s)
Max
.
Gain
(dB)
Min
.
Gain

(dB)
Max
 Max. Output Amplitude (ns)Min.
Output
Output  Amplitude (ns)
32
14.92502235150-
5
14.1none
29
54none
10.12501485150-
3
10.
0
9none
77
76none
3.2250480150
0
-3.
2
3none176none
12501501500.2-3
.00
261
171
172
0.32250481500.2-3
.00
261
171
172
0.1320151500.2-3
.00
333
332
221
222
0.032100082500.2-3
.00
1029
1028
702
703
0.01200044000.2-3
.00
2052
1410
1411
0.00322000412500.2-3
.00
2052
1410
1411


SyncE Wander Transfer using Tones: Option 2

Parameters used:

  • Maximum bandwidth: 0.1Hz
  • Minimum bandwidth: none specified
  • Maximum gain peaking: 0.2dB
  • Minimum gain in pass-band: no criteria, since no minimum bandwidth specified
  • Noise generation allowance: ±20ns
  • Two points per decade, extending over 2 decades below the -3dB point
  • Sampling rate: 30Hz

Frequency
(Hz)

Amplitude
(ns)

Test Time
(Cycles)

Test Time
(s)

Max. Gain
(dB)

Min. Gain
(dB)

Max. Output Amplitude
(ns)

Min. Output Amplitude
(ns)

3.2

300

480

150

-30.1

none

30

none

1

301

150

150

-20.0

none

50

none

0.32

303

48

150

-10.5

none

111

none

0.1

308

15

150

-3.0

none

238

none

0.032

325

8

250

0.2

none

353

none

0.01

380

4

400

0.2

none

409

none

0.0032

550

4

1250

0.2

none

583

none

0.001

1000

3

3000

0.2

none

1044

none

0.00032

1007

3

9375

0.2

none

1051

none


On this page: