Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

SyncE Wander Tolerance using Tones: Option 1 and Enhanced

Parameters used:

  • Measured at each corner point in G.8262/Figure 7
  • At least one point per decade

Frequency (Hz)

MTIE Observation Interval (s)

Amplitude

(ns)

Test Time

(Cycles)

Test Time

(s)

10

0.032

250

1500

150

1

0.32

250

150

150

0.13

2.5

250

20

154

0.016

20

2000

4

250

0.0032

100

2000

4

1250

0.0008

400

2000

3

3750

0.00032

1000

5000

3

9375

  • No labels