- Measured at each corner point in G.8262/Figure 7
- At least one point per decade
Frequency | MTIE Observation Interval (s) | Amplitude | Test Time | Test Time |
---|---|---|---|---|
3.2 | 0.1 | 300 | 480 | 150 |
0.32 | 1 | 303 | 150 | 150 |
0.032 | 10 | 325 | 8 | 250 |
0.0032 | 100 | 550 | 4 | 1250 |
0.0011 | 280 | 1000 | 3 | 2727 |
0.00032 | 1000 | 1007 | 3 | 9375 |
SyncE Wander Transfer using Tones: Option 2
Parameters used:
- Maximum bandwidth: 0.1Hz
- Minimum bandwidth: none specified
- Maximum gain peaking: 0.2dB
- Minimum gain in pass-band: no criteria, since no minimum bandwidth specified
- Noise generation allowance: ±20ns
- Two points per decade, extending over 2 decades below the -3dB point
- Sampling rate: 30Hz
Frequency (Hz) | Amplitude (ns) | Test Time (Cycles) | Test Time (s) | Max. Gain (dB) | Min. Gain (dB) | Max. Output Amplitude (ns) | Min. Output Amplitude (ns) |
3.2 | 300 | 480 | 150 | -30.1 | none | 30 | none |
1 | 301 | 150 | 150 | -20.0 | none | 50 | none |
0.32 | 303 | 48 | 150 | -10.5 | none | 111 | none |
0.1 | 308 | 15 | 150 | -3.0 | none | 238 | none |
0.032 | 325 | 8 | 250 | 0.2 | none | 353 | none |
0.01 | 380 | 4 | 400 | 0.2 | none | 409 | none |
0.0032 | 550 | 4 | 1250 | 0.2 | none | 583 | none |
0.001 | 1000 | 3 | 3000 | 0.2 | none | 1044 | none |
0.00032 | 1007 | 3 | 9375 | 0.2 | none | 1051 | none |