Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Modified 1000 tau to be 1007 to match the MTIE Mask for Opt2 and spreadsheet on SharePoint.

SyncE Wander Tolerance using Tones: Option 1 and Enhanced (Tolerance Level 2)

Note that for Enhanced SyncE clocks specified in G.8262.1, there are two tolerance levels; level 2 is the same as the tolerance for standard SyncE clocks as specified in G.8262.

Parameters used:

  • Measured at each corner point in G.8262/Figure 7
  • At least one point per decade

Frequency (Hz)

MTIE Observation Interval (s)

Amplitude
(ns)

Test Time
(Cycles)

Test Time
(s)

10

0.032

250

1500

150

1

0.32

250

150

150

0.13

2.5

250

20

154

0.016

20

2000

4

250

0.0032

100

2000

4

1250

0.0008

400

2000

3

3750

0.00032

1000

5000

3

9375

Image Modified

SyncE Wander

...

Tolerance using Tones:

...

Enhanced (Tolerance Level 1)

Parameters used:

  • Maximum bandwidth: 10Hz
  • Minimum bandwidth: 1Hz
  • Maximum gain peaking: 0.2dB
  • Minimum gain In pass-band: -3dB
  • Noise generation allowance: ±20ns
  • Two points per decade, extending more than 2 decades below the -3dB point
  • Sampling rate: 30Hz
  • Measured at each corner point in G.8261/Figure 17
  • At least one point per decade


Frequency (Hz)

MTIE Observation Interval (s)

Amplitude

(ns)

Test Time

(Cycles)

Test Time

(s)

...

14.9

...

250

...

2235

...

150

...

-5.1

...

none

...

160

...

none

...

9.9

...

250

...

1485

...

150

...

...

Min. Gain
(dB)

...

Max. Output Amplitude (ns)

...

Min. Output Amplitude (ns)

3.

...

none

...

198

...

none

...

2

...

250

...

480

...

0.

...

none

...

276

...

none

1

...

50

...

1500

...

469

0.

...

-3.00

...

276

...

156

...

0.32

...

250

...

32

1

50

150

150

0.

...

-3.00

...

276

...

156

...

0.1

...

053

6

300

15

...

283

0.

...

-3.00

...

348

...

206

...

032

...

0.01

...

2000

...

4

...

10

...

8

...

250

...

0.2

...

-3.00

...

1044

...

687

300

4

250

0.

...

-3.00

...

2067

...

1395

...

0.0032

...

0032

100

300

4

1250

0.

...

-3.00

...

2067

...

1395

Image Removed

SyncE Wander Transfer using Tones: Enhanced

Parameters used:

  • Maximum bandwidth: 3Hz
  • Minimum bandwidth: 1Hz
  • Maximum gain peaking: 0.2dB
  • Minimum gain In pass-band: -3dB
  • Noise generation allowance: ±5ns
  • Two points per decade, extending more than 2 decades below the -3dB point
  • Sampling rate: 1kHz

...

Frequency
(Hz)

...

Amplitude
(ns)

...

Test Time
(Cycles)

...

Test Time
(s)

...

Max. Gain
(dB)

...

Min. Gain
(dB)

...

Max. Output Amplitude (ns)

...

Min. Output Amplitude (ns)

...

32

...

250

...

2235

...

150

...

-5.1

...

none

...

29

...

none

...

10

...

250

...

1485

...

150

...

-3.0

...

none

...

77

...

none

...

3.2

...

250

...

480

...

150

...

0.2

...

none

...

176

...

none

...

1

...

250

...

150

...

150

...

0.2

...

-3.00

...

261

...

171

...

0.32

...

250

...

48

...

150

...

0.2

...

-3.00

...

261

...

171

...

0.1

...

320

...

15

...

150

...

0.2

...

-3.00

...

333

...

221

...

0.032

...

1000

...

8

...

250

...

0.2

...

-3.00

...

1029

...

702

...

0.01

...

2000

...

4

...

400

...

0.2

...

-3.00

...

2052

...

1410

...

0.0032

...

2000

...

4

...

1250

...

0.2

...

-3.00

...

2052

...

1410

Image Removed

00032

1000

300

3

9375


Wander Tolerance based on a chain of enhanced clocks:

Image AddedFigure 17/G.8261 - Network limit for wander (MTIE) at enhanced synchronous equipment clock interfaces


SyncE Wander Tolerance using Tones: Option 2

More information regarding how the tones were selected can be found: G.8262: Wander Tolerance and Transfer for Option II Clocks

Parameters used:

...

  • Tone amplitudes equal to MTIE mask value at the relevant observation interval of G.824/Figure 3
  • At least one point per decade

Frequency
(Hz)

MTIE Observation Interval (s)

Amplitude
(ns)

Test Time
(Cycles)

Test Time
(s)

3.2

0.1

300

480

150

0.32

1

303

150

150

0.032

10

325

8

250

0.0032

100

550

4

1250

0.0011

280

1000

3

2727

0.00032

1000

1007

3

9375


Image Modified

SyncE Wander Transfer using Tones: Option 2

Parameters used:

  • Maximum bandwidth: 0.1Hz
  • Minimum bandwidth: none specified
  • Maximum gain peaking: 0.2dB
  • Minimum gain in pass-band: no criteria, since no minimum bandwidth specified
  • Noise generation allowance: ±20ns
  • Two points per decade, extending over 2 decades below the -3dB point
  • Sampling rate: 30Hz

...

Frequency
(Hz)

...

Amplitude
(ns)

...

Test Time
(Cycles)

...

Test Time
(s)

...

Max. Gain
(dB)

...

Min. Gain
(dB)

...

Max. Output Amplitude
(ns)

...

Min. Output Amplitude
(ns)

...

3.2

...

300

...

480

...

150

...

-30.1

...

none

...

30

...

none

...

1

...

301

...

150

...

150

...

-20.0

...

none

...

50

...

none

...

0.32

...

303

...

48

...

150

...

-10.5

...

none

...

111

...

none

...

0.1

...

308

...

15

...

150

...

-3.0

...

none

...

238

...

none

...

0.032

...

325

...

8

...

250

...

0.2

...

none

...

353

...

none

...

0.01

...

380

...

4

...

400

...

0.2

...

none

...

409

...

none

...

0.0032

...

550

...

4

...

1250

...

0.2

...

none

...

583

...

none

...

0.001

...

1000

...

3

...

3000

...

0.2

...

none

...

1044

...

none

...

0.00032

...

1007

...

3

...

9375

...

0.2

...

none

...

1051

...

none

...



On this page:

Table of Contents