SyncE Wander Tolerance using Tones: Option 1 and Enhanced (Tolerance Level 2)
(Note that for Enhanced SyncE clocks (specified in G.8262.1), there are two tolerance levels. Level 2 is the same as the tolerance for standards SyncE clocks (specified in G.8262).
Parameters used:
Measured at each corner point in G.8262/Figure 7
At least one point per decade
Frequency (Hz)
MTIE Observation Interval (s)
Amplitude (ns)
Test Time (Cycles)
Test Time (s)
10
0.032
250
1500
150
1
0.32
250
150
150
0.13
2.5
250
20
154
0.016
20
2000
4
250
0.0032
100
2000
4
1250
0.0008
400
2000
3
3750
0.00032
1000
5000
3
9375
SyncE Wander Tolerance using Tones: Enhanced (Tolerance Level 1)
Parameters used:
Measured at each corner point in G.8261/Figure 17
At least one point per decade
Frequency (Hz)
MTIE Observation Interval (s)
Amplitude
(ns)
Test Time
(Cycles)
Test Time
(s)
3.2
0.1
50
1500
150
0.32
1
50
150
150
0.53
6
300
20
154
0.032
10
300
4
250
0.0032
100
300
4
1250
0.00032
1000
300
3
9375
Wander Tolerance based on a chain of enhanced clocks:
Figure 17/G.8261 - Network limit for wander (MTIE) at enhanced synchronous equipment clock interfaces
SyncE Wander Transfer using Tones: Option 1
Parameters used:
Maximum bandwidth: 10Hz
Minimum bandwidth: 1Hz
Maximum gain peaking: 0.2dB
Minimum gain In pass-band: -3dB
Noise generation allowance: ±20ns
Two points per decade, extending more than 2 decades below the -3dB point
Sampling rate: 30Hz
Frequency (Hz)
Amplitude (ns)
Test Time (Cycles)
Test Time (s)
Max. Gain (dB)
Min. Gain (dB)
Max. Output Amplitude (ns)
Min. Output Amplitude (ns)
14.9
250
2235
150
-5.1
none
160
none
9.9
250
1485
150
-3.0
none
198
none
3.2
250
480
150
0.2
none
276
none
1
250
150
150
0.2
-3.00
276
156
0.32
250
48
150
0.2
-3.00
276
156
0.1
320
15
150
0.2
-3.00
348
206
0.032
1000
8
250
0.2
-3.00
1044
687
0.01
2000
4
400
0.2
-3.00
2067
1395
0.0032
2000
4
1250
0.2
-3.00
2067
1395
SyncE Wander Transfer using Tones: Enhanced
Parameters used:
Maximum bandwidth: 3Hz
Minimum bandwidth: 1Hz
Maximum gain peaking: 0.2dB
Minimum gain In pass-band: -3dB
Noise generation allowance: ±5ns
Two points per decade, extending more than 2 decades below the -3dB point
Sampling rate: 1kHz
Frequency (Hz)
Amplitude (ns)
Test Time (Cycles)
Test Time (s)
Max. Gain (dB)
Min. Gain (dB)
Max. Output Amplitude (ns)
Min. Output Amplitude (ns)
32
250
2235
150
-5.1
none
29
none
10
250
1485
150
-3.0
none
77
none
3.2
250
480
150
0.2
none
176
none
1
250
150
150
0.2
-3.00
261
171
0.32
250
48
150
0.2
-3.00
261
171
0.1
320
15
150
0.2
-3.00
333
221
0.032
1000
8
250
0.2
-3.00
1029
702
0.01
2000
4
400
0.2
-3.00
2052
1410
0.0032
2000
4
1250
0.2
-3.00
2052
1410
SyncE Wander Tolerance using Tones: Option 2
Parameters used:
Measured at each corner point in G.8262/Figure 7
At least one point per decade
Frequency (Hz)
MTIE Observation Interval (s)
Amplitude (ns)
Test Time (Cycles)
Test Time (s)
3.2
0.1
300
480
150
0.32
1
303
150
150
0.032
10
325
8
250
0.0032
100
550
4
1250
0.0011
280
1000
3
2727
0.00032
1000
1007
3
9375
SyncE Wander Transfer using Tones: Option 2
Parameters used:
Maximum bandwidth: 0.1Hz
Minimum bandwidth: none specified
Maximum gain peaking: 0.2dB
Minimum gain in pass-band: no criteria, since no minimum bandwidth specified
Noise generation allowance: ±20ns
Two points per decade, extending over 2 decades below the -3dB point