Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 17 Current »

These patterns are for use with Paragon-neo to test O-DU devices intended for use in an LLS-C1 or LLS-C2 topology (mandatory requirement) or LLS-C3 or LLS-C4 (optional) as per the requirements of the O-RAN CONF document clause 3.3.7.

These patterns are also built-in to Paragon-neo O-RAN Conformance Test App. The CAT masks for use with these impairments are built-in to CATv30 and Paragon-neo R10.

There are sinusoidal model patterns and a noise model pattern. For testing an O-DU at G.8271.1 Reference Point C, O-RAN CONF advises that the noise model pattern is more representative of real network conditions and transients, and therefore a more effective test of the O-DU under emulated network conditions.

Noise Model Pattern

This pattern meets the network limit mask defined in ITU-T G.8271.1 Table 7-1/Figure 7-2, it has been generated using the time/phase error noise model method described in G.8273.2 Amd1 (02/2022) Appendix IX and includes the effect of a suppressed physical layer re-arrangement transient on the PTP time error.

  File Modified

Sinusoidal Model Patterns (from WG4.CONF v09.00)

These patterns use the sinusoidal tones specified in O-RAN CONF v09.00 Table 3.3.7-1 to create the time/phase errors. They will be built-in to Paragon-neo from R12.

The amplitudes used in these patterns have been modified from the earlier version (below) to better represent the limits defined by the MTIE mask from G.8271.1; the frequencies used have not changed.

These new amplitudes are slightly higher than the previous values, and may therefore cause an O-DU that previously marginally-passed to now fail. Compliance with WG4.CONF requires that these new patterns are used for testing.

  File Modified
You are not logged in. Any changes you make will be marked as anonymous. You may want to Log In if you already have an account.
No files shared here yet.
  • Drag and drop to upload or browse for files
  • Superseded Sinusoidal Model Patterns (from WG4.CONF v08.00 and earlier)

    These patterns use the sinusoidal tones specified in O-RAN CONF v08.00 and earlier, Table 3.3.7-1 to create the time/phase errors. They are built-in to Paragon-neo R10 and R11.

      File Modified
    You are not logged in. Any changes you make will be marked as anonymous. You may want to Log In if you already have an account.
    No files shared here yet.
  • Drag and drop to upload or browse for files
    • No labels