SyncE Wander Tolerance using Tones: Option 1 and Enhanced
Parameters used:
- Measured at each corner point in G.8262/Figure 7
- At least one point per decade
Frequency (Hz) | MTIE Observation Interval (s) | Amplitude (ns) | Test Time (Cycles) | Test Time (s) |
10 | 0.032 | 250 | 1500 | 150 |
1 | 0.32 | 250 | 150 | 150 |
0.13 | 2.5 | 250 | 20 | 154 |
0.016 | 20 | 2000 | 4 | 250 |
0.0032 | 100 | 2000 | 4 | 1250 |
0.0008 | 400 | 2000 | 3 | 3750 |
0.00032 | 1000 | 5000 | 3 | 9375 |