ITU-T G.8262 (SyncE Clock Performance) One-Page Summary

ITU-T G.8262 (SyncE Clock Performance) One-Page Summary

Title: Timing characteristics of a synchronous equipment slave clocks

On this page:

Summary

  • Synchronous Equipment Clock performance specification, covering both synchronous Ethernet Equipment clocks (EEC) and synchronous OTN Equipment Clocks (OEC)

  • Identical in performance to the SDH Equipment Clock specification defined in G.813

  • Specifies frequency accuracy, noise generation, noise tolerance, noise transfer, phase transients

  • Operates over most Ethernet interfaces from 100Mbit/s to 100Gbit/s

Status

Key Contents

  • Frequency accuracy (free-run): 4.6 ppm

  • Wander Generation (Figures 1 and 2):

  • Wander Tolerance (Figure 5):

  • Wander transfer: Low pass filter,

    • EEC Option 1 (Europe): 1 to 10 Hz

    • EEC Option 2 (N. America): max. 0.1 Hz

  • Jitter Generation (Table 6):

Interface

Measuring Filter

Peak-to-Peak amplitude (UI)

Interface

Measuring Filter

Peak-to-Peak amplitude (UI)

1G

2.5kHz to 10MHz

0.50

10G

20kHz to 80MHz

0.50

25G

20kHz to 200MHz

1.2

  • Jitter Tolerance (Figure 9):

  • Holdover (Figure 13):