The Paragon-X GUI shows a number of green/red indicators, which I believe are referred to as 'soft LEDs'. What do these actually mean in the Connected Slave and Connected Master panels?

Answer:

The meaning of the LEDs in these panels varies according to whether the test is running in multicast or unicast mode:

Multicast:

Grey

P-X master was receiving Del_Req messages from the Slave but the P-X master is now inactive

Green

P-X master is receiving Del_Req messages from the Slave

Red

P-X master was receiving Del_Req messages from the Slave but is no longer receiving them

Unicast Auto:

Grey

P-X master had granted the Slave unicast messaging but the P-X master is now inactive

Green

P-X master has granted the Slave unicast messaging

Red

P-X master had granted the Slave unicast messaging but this has expired or the slave cancelled it

Unicast Forced:

Grey

Slave not enabled in configuration, or P-X master is inactive

Green

P-X master is sending Announce/Sync messages to the slave

Red

(Not used)