ITU-T G.8262.1 (Enhanced SyncE) One-Page Summary

ITU-T G.8262.1 (Enhanced SyncE) One-Page Summary

Title: Timing characteristics of enhanced synchronous equipment slave clocks

Summary

  • Enhanced Synchronous Equipment Clock performance specification, covering both enhanced synchronous Ethernet Equipment clocks (eEEC) and OTN Equipment Clocks (eOEC)

  • Performance meets the requirements of 5G mobile cellular systems

  • Specifies frequency accuracy, noise generation, noise tolerance, noise transfer, phase transients

  • Operates over most Ethernet interfaces from 100Mbit/s to 100Gbit/s

Status

Key Contents

  • Frequency accuracy (free-run): 4.6 ppm

  • Wander Generation (Figures 1 and 2):

  • Wander Tolerance (Figure 3):

 

 

 

 

 

 

 

 

 

 

 

  • Wander Transfer: Low pass filter, 1 to 3 Hz

  • Jitter Generation (Table 3):

Interface

Measuring filter

Peak-to-peak amplitude (UI)

Interface

Measuring filter

Peak-to-peak amplitude (UI)

1G

2.5kHz to 10MHz

0.5

10G

20kHz to 80MHz

For further study

25G

20kHz to 200MHz

For further study

  • Jitter Tolerance (Figure 6):

  • Holdover (Figure 8):