Sentinel: Frequently asked questions regarding monitor mode

Sentinel: Frequently asked questions regarding monitor mode



Monitor mode requires the use of an optical splitter or electrical TAP to break into the Ethernet connection between the network and the T-TSC.  

Sentinel requires two Packet modules to run in monitor mode. The TAP / splitter connects the Tx path of the PTP GM to the Rx input of one Packet module and the Tx path of the T-TSC to the Rx input of the second Packet module using standard Ethernet copper or fibre cables.  

There is no requirement for the connections from the TAP to be connected in a specific order:  

  • The Sentinel GUI displays a single widget for the paired Packet modules

  • Sync, FwUp and Dresp indicators will appear in the status LEDs for Packet module connected to the PTP GM to T-TSC traffic 

  • Dreq indicator will appear in the status LEDs for Packet module connected to the the T-TSC to PTP GM traffic 

  • Fwd PDV, Rev PDV, Path Delay and 2Way TE results will always appear on the leftmost channel i.e. channel A or channel C if no PTP card is in channel A slot.

Monitor mode is enabled through the Settings→Mode page:

The following screen shot shows the 2WayTE result from an Ethernet multicast flow with the PTP GM connection on channel E and the T-TSC connection on channel C.

Related articles







Related content

Sentinel
Read with this
Sentinel: why can't I see ESMC messages?
Sentinel: why can't I see ESMC messages?
More like this
Sentinel: How do I use Sentinel captures as Paragon-X Impairment Patterns?
Sentinel: How do I use Sentinel captures as Paragon-X Impairment Patterns?
More like this
Sentinel: Releases
Sentinel: Releases
More like this
Sentinel: Initial troubleshooting
Sentinel: Initial troubleshooting
More like this
Sentinel: 100M Optical Interface Offset (Resolved)
Sentinel: 100M Optical Interface Offset (Resolved)
More like this