Sentinel: Frequently asked questions regarding monitor mode
Monitor mode requires the use of an optical splitter or electrical TAP to break into the Ethernet connection between the network and the T-TSC.
Sentinel requires two Packet modules to run in monitor mode. The TAP / splitter connects the Tx path of the PTP GM to the Rx input of one Packet module and the Tx path of the T-TSC to the Rx input of the second Packet module using standard Ethernet copper or fibre cables.
There is no requirement for the connections from the TAP to be connected in a specific order:
The Sentinel GUI displays a single widget for the paired Packet modules
Sync, FwUp and Dresp indicators will appear in the status LEDs for Packet module connected to the PTP GM to T-TSC traffic
Dreq indicator will appear in the status LEDs for Packet module connected to the the T-TSC to PTP GM traffic
Fwd PDV, Rev PDV, Path Delay and 2Way TE results will always appear on the leftmost channel i.e. channel A or channel C if no PTP card is in channel A slot.
Monitor mode is enabled through the Settings→Mode page:
The following screen shot shows the 2WayTE result from an Ethernet multicast flow with the PTP GM connection on channel E and the T-TSC connection on channel C.