What Frequencies should be used for testing SyncE Wander Transfer?

What Frequencies should be used for testing SyncE Wander Transfer?

SyncE Wander Transfer using Tones: Option 1

Parameters used:

  • Maximum bandwidth: 10Hz

  • Minimum bandwidth: 1Hz

  • Maximum gain peaking: 0.2dB

  • Minimum gain In pass-band: -3dB

  • Noise generation allowance: ±20ns

  • Two points per decade, extending more than 2 decades below the -3dB point

  • Sampling rate: 30Hz

Frequency
(Hz)

Amplitude
(ns)

Test Time
(Cycles)

Test Time
(s)

Max. Gain
(dB)

Min. Gain
(dB)

Max. Output Amplitude (ns)

Min. Output Amplitude (ns)

Frequency
(Hz)

Amplitude
(ns)

Test Time
(Cycles)

Test Time
(s)

Max. Gain
(dB)

Min. Gain
(dB)

Max. Output Amplitude (ns)

Min. Output Amplitude (ns)

14.9

250

2235

150

-5.1

none

160

none

10.1

250

1485

150

-3.1

none

198

none

3.2

250

480

150

0.2

none

276

none

1

250

150

150

0.2

-3.00

276

156

0.32

250

48

150

0.2

-3.00

276

156

0.1

320

15

150

0.2

-3.00

348

206

0.032

1000

8

250

0.2

-3.00

1044

687

0.01

2000

4

400

0.2

-3.00

2067

1395

0.0032

2000

4

1250

0.2

-3.00

2067

1395

SyncE Wander Transfer using Tones: Enhanced

Parameters used:

  • Maximum bandwidth: 3Hz

  • Minimum bandwidth: 1Hz

  • Maximum gain peaking: 0.2dB

  • Minimum gain In pass-band: -3dB

  • Noise generation allowance: ±5ns

  • Two points per decade, extending more than 2 decades below the -3dB point

  • Sampling rate: 1kHz

Frequency
(Hz)

Amplitude
(ns)

Test Time
(cycles)

Test Time
(s)

Max Gain
(dB)

Min Gain (dB)

 Max. Output Amplitude (ns)

Min. Output  Amplitude (ns)

Frequency
(Hz)

Amplitude
(ns)

Test Time
(cycles)

Test Time
(s)

Max Gain
(dB)

Min Gain (dB)

 Max. Output Amplitude (ns)

Min. Output  Amplitude (ns)

14.9

250

2235

150

-14.1

none

54

none

10.1

250

1485

150

-10.9

none

76

none

3.2

250

480

150

-3.3

none

176

none

1

250

150

150

0.2

-3

261

172

0.32

250

48

150

0.2

-3

261

172

0.1

320

15

150

0.2

-3

332

222

0.032

1000

8

250

0.2

-3

1028

703

0.01

2000

4

400

0.2

-3

2052

1411

0.0032

2000

4

1250

0.2

-3

2052

1411

SyncE Wander Transfer using Tones: Option 2

Parameters used:

  • Maximum bandwidth: 0.1Hz

  • Minimum bandwidth: none specified

  • Maximum gain peaking: 0.2dB

  • Minimum gain in pass-band: no criteria, since no minimum bandwidth specified

  • Noise generation allowance: ±20ns

  • Two points per decade, extending over 2 decades below the -3dB point

  • Sampling rate: 30Hz

Frequency
(Hz)

Amplitude
(ns)

Test Time
(Cycles)

Test Time
(s)

Max. Gain
(dB)

Min. Gain
(dB)

Max. Output Amplitude
(ns)

Min. Output Amplitude
(ns)

Frequency
(Hz)

Amplitude
(ns)

Test Time
(Cycles)

Test Time
(s)

Max. Gain
(dB)

Min. Gain
(dB)

Max. Output Amplitude
(ns)

Min. Output Amplitude
(ns)

3.2

300

480

150

-30.1

none

30

none

1

301

150

150

-20.0

none

50

none

0.32

303

48

150

-10.5

none

111

none

0.1

308

15

150

-3.0

none

238

none

0.032

325

8

250

0.2

none

353

none

0.01

380

4

400

0.2

none

409

none

0.0032

550

4

1250

0.2

none

583

none

0.001

1000

3

3000

0.2

none

1044

none

0.00032

1007

3

9375

0.2

none

1051

none